I blogged several weeks ago about considering a VFD as an option for a new-to-me Powermatic 66 that was equipped with a 5hp 3ph motor. I appreciate the advice that you all offered and I went as far as receiving the shipment of the VFD to power the machine. But something wasn’t sitting right about the situation. It didn’t feel right to “bandaid” something that will truly be a lifetime machine. So, I sent the VFD back (actually it’s sitting in the passenger seat of my car, yikes!) and pulled the trigger on a new 3hp 1ph motor from mmToolParts. The motor itself was just $150 more than the VFD I had purchased, a small price difference for a lifetime of use in my opinion, and about $50 less expensive than the motor direct from Powermatic in Tennesee.
I’d like to say a kind word about the folks at mmToolParts. They were really knowledgable and patient on the phone and shipped the motor the same day. They are a family business and have really expanded their eCommerce presence in a great way. They even had a video about the motor swap on their YouTube channel. Anway, thanks to Mike over there, he was great.
The swap was really simple. The 1ph motor had two potential configurations to get the motor spinning the correct way, of course we wired it up the wrong way the first time. It was just a matter of swapping a couple of leads and we were in business. The motor mounts to the trunion with a faceplate and just two bolts. We did spring for a new magnetic switch that was recommended from Powermatic. but after pulling the old switch apart we realized we could have reused the old one.
Now it’s done. I shouldn’t have to think about this motor for a long time. I won’t have to listen to the fan on a VFD or worry about over-complicated electronics on a machine that simply turns on and off. Now it’s time to finish installing the fence!
If you’re looking for expert advice on how to setup your table saw and get the most out of your machine, Doug Dale’s video is the way to go, check it out in our store: Power Tool Essentials: The Table Saw.
Here are some supplies and tools we find essential in our everyday work around the shop. We may receive a commission from sales referred by our links; however, we have carefully selected these products for their usefulness and quality.
If you would have kept the old contactor, its over load or heater setup would need to be adjusted or the heaters replaced. The rating for a single phase motor at the same hp is almost double the amps of the 3 phase motor. Best to check the FLA ot the motor. Just info in case anyone else decides to just replace a 3ph motor with a single phase motor.
You are correct, it all depends on the hardware you have. The switches on my bench were within range of one another on their adjustable breaker points.